Electrical network analysers

01

PECA 11 | DIVA 11 | For all types of AC electrical networks

  • Universal power supply
  • 2 isolated analog outputs +/-20mA + 1 isolated analog output 0/20mA
  • 5 relay outputs
  • 1 isolated digital output RS485 Modbus/Jbus communications
  • 1 Ethernet IEC 61850 output / Profibus output
  • 3 logic inputs
  • Harmonics analysis

02

PECA 11 DC | DIVA 11 DC | DC networks

  • Universal power supply
  • 2 isolated analog outputs +/-20mA + 1 isolated analog output 0/20mA
  • 5 relay outputs
  • 1 isolated digital output RS485 Modbus/Jbus communications
  • 1 Ethernet output / Profibus output
  • 3 logic inputs

03

PECA 11 D | DIVA 11 D | Analysis and display of the disturbances

  • Universal power supply
  • 5 relay outputs
  • 1 isolated digital output RS485 Modbus/Jbus communications
  • 1 Ethernet output

04

PECA 7 | DIVA 7 | Voltmeter - Ammeter

  • Universal power supply
  • 2 relay outputs
  • 1 isolated digital output RS485 Modbus/Jbus communications

05

PECA 5 | DIVA 5 | Single or 3-phase balanced networks

  • 1 isolated analog output 0-4-20mA or 0-10V
  • 2 or 4 relay outputs
  • 1 isolated digital output RS485 Modbus/Jbus communications
  • 2 isolated logic inputs
  • Bargraph display

06

PECA 5C | DIVA 5C | DC networks

  • 1 isolated analog output 0-4-20mA or 0-10V
  • 2 or 4 relay outputs
  • 1 isolated digital output RS485 Modbus/Jbus communications
  • 2 isolated logic inputs
  • Bargraph display

07

PECA 15E | DIVA 15E | For all types of AC electrical networks

  • 1 isolated analog output +/-20mA
  • 2 relay outputs
  • 1 isolated digital output RS422/485 Modbus/Jbus communications
  • Harmonics analysis

08

PECA 15PBUS | DIVA 15PBUS | Profibus output analyser

  • 1 isolated analog output +/-20mA
  • 2 relay outputs
  • 1 Profibus output
  • Harmonics analysis

09

PECA 17 | DIVA 17 | 2 outputs RS485 Modbus communications

  • 1 isolated analog output +/-20mA
  • 1 relay output
  • 2 isolated digital outputs RS422/485 Modbus/Jbus communications
  • Harmonics analysis

10

STREC20 | Energy meter

  • 1 isolated analog output 0-4-20mA or 0-10V
  • 2 relay outputs
  • 1 isolated digital output RS485 Modbus/Jbus communications

11

PECA 30E | For all types of AC electrical networks

  • 3 isolated analog outputs +/-20mA
  • 3 relay outputs: alarm relay or pulses
  • 1 isolated digital output RS422/485 Modbus/Jbus communications

12

PECA 301 | For all types of AC electrical networks – up to 6 analog outputs and 4 relays

  • Isolated analog outputs +/-20mA
  • Relay outputs: alarm relay or pulses
  • 1 isolated digital output RS422/485 Modbus/Jbus communications
  • 3 logic inputs

13

PECA 3001 | For all types of AC electrical networks – up to 9 analog outputs and 6 relays

  • Isolated analog outputs +/-20mA
  • Relay outputs: alarm relay or pulses
  • 1 isolated digital output RS422/485 Modbus/Jbus communications
  • 3 logic inputs

YOU SEARCH A PRODUCT?

Search
Generic filters

Date of last modification: 28 July 2017