Intrinsically Safe Signal Conditioner µC-SI 30I

The µC-SI series has intrinsically safe inputs: they are associated equipment to be placed in a safe area or ATEX/IECEx area 2.

Readily programmable on the front face with the micro-console or McVision PC software.

TECHNICAL SPECIFICATIONS

  • Certification ATEX CE 0344 Ex II (1) GD [Ex ia] IIC and [Ex iaD]
  • IS input: Namur or contact
  • Frequency: from 0.01 Hz to 50 kHz (Namur), from 0.01 Hz to 20 Hz (contact)
  • Isolated analog output in mA active
  • Accuracy class: 0.025% of the measure
  • Scale factor programmable
  • Special linearisation on 20 points
  • For DIN rail mounting
  • Programmable by software or µconsole (optional)